DV-W2xE Updater procedure

1. Notes
	Check the drive model and Binary file before executing the update program.
	Do not turn off the drive before the update is completed.	

2. Configuration
	PC: IDE PORT recomandation as indicated below.
		Primary Port: Any configuration
		Secondary Port: Master: DV-W2xE
				Slave: No connection
		Do not connect target drive with the same port as HDD.
		In case that target drive is connected to Slave side, update itself shall be completed 
		with no problem, however display may have malfunction after complete message is indicated. 
	OS: Windows 98SE (Startup FD is required)

3. To make FDD for update
	Prepare 2 blank FD.
	One for Startup disk (include updater execute file).
	Another one for binary file.
3.1	Prepare Startup FD.
	Format a FD with format type "Copy system files only" selected
	Format another FD for binary file with any format type.
3.2	Copy following 2 files to Startup FD from Windows folder.
	Himem.sys
	Ansi.sys
3.3	Extract attached file (if these files are compressed) and copy following files to Startup FD.
	Config.sys
	Autoexec.bat
	Updater.exe
	Copy binary file to another formatted FD.
 
4. Update
4.1	Connect target DV-W2xE to IDE port that HDD is not connected. And Turn on System with 
	Startup FD inserted.
4.2	Press eject button to open tray to make sure.
4.3	Replace Startup FD with binary file FD while updater is launched.
4.4	Follow the menue and select DV-W2xE and Binary file to be updated.
4.4	Confirm [BIN FILE] [TG.INQUIRY] indication then press "y" key.
4.5	Update is completed when display indicates "Update Complete,,,,!"
	If target drive is connected to Slave side, it may not indicate message 
	"Update Complete,,,,!".  In that case, please follow procedure below to confirm the update.
	* After "Syncronize Microcode" is indicated, Drive LED turns on as follwing order.
	  Green(Blinking) -> Amber(Dark) -> Amber(Light) -> Turn off
	* When turn off/on, Inquirey data is correctly indicated and recognize the media correctly.
4.6	Turn off PC. 